R134a R407C Gas in Kenya, Tanzania and Uganda

Technical Specifications

Specification R134a R407C
Refrigerant Type HFC HFC blend
Chemical Name 1,1,1,2-Tetrafluoroethane Blend of R32, R125, and R134a
Chemical Formula C₂H₂F₄ Refrigerant blend
CAS Number 811-97-2 75-10-5, 354-33-6, and 811-97-2 for the individual components
ASHRAE Safety Classification A1 A1
Normal Boiling Point Approximately −26.1°C Approximately −43.6°C
Ozone Depletion Potential 0 0
Global Warming Potential Approximately 1,430 Approximately 1,774
Common Applications Compatible refrigeration systems, chillers, and certain automotive air-conditioning systems Compatible air-conditioning systems, heat pumps, and selected refrigeration systems
System Compatibility Equipment designed or approved for R134a Equipment designed or approved for R407C

GWP values are based on commonly cited IPCC Fourth Assessment Report figures. Values may differ by assessment standard. Consult the manufacturer’s documentation for the exact product supplied.

Prices are confirmed on request. Send us the size and quantity you need.

Description

R134a R407C Gas in Kenya, Tanzania and Uganda

Product Description

R134a and R407C Refrigerant Gas are used in compatible refrigeration, air-conditioning, and cooling systems. Metraflex Industrial Suppliers provides product information about R134a and R407C Refrigerant Gas for customers in Kenya, Tanzania, and Uganda.

R134a and R407C have different operating characteristics and equipment requirements. Always confirm the refrigerant specified by the equipment manufacturer before servicing or recharging a system.

Key Features of R134a R407C Gas
  • R134a: Single-component HFC refrigerant.
  • R407C: HFC refrigerant blend comprising R32, R125, and R134a.
  • Ozone depletion potential: Both have an ODP of zero.
  • Applications: Refrigeration, air conditioning, and compatible cooling equipment.
  • System compatibility: Each refrigerant must be used only in equipment designed or approved for it.
  • Technical documentation: Refer to the relevant manufacturer’s technical data sheet and safety data sheet.
  • Environmental considerations: Both refrigerants have global warming potential and may be subject to refrigerant management regulations.
Benefits of R134a R407C Gas
  • Support cooling performance in compatible equipment.
  • Offer established operating characteristics for their intended applications.
  • Provide options for different refrigeration and air-conditioning system designs.
  • Can be selected according to equipment specifications and manufacturer recommendations.

Actual performance depends on the system design, operating conditions, correct refrigerant charge, and maintenance.

Common Applications of R134a Applications
  • Compatible refrigeration equipment.
  • Commercial and industrial chillers.
  • Certain automotive air-conditioning systems.
  • Selected cooling and temperature-control applications
Applications of R134a R407C Gas
  • Compatible residential and commercial air conditioners.
  • Selected heat-pump systems.
  • Commercial HVAC installations.
  • Certain refrigeration systems designed for R407C.
  • Some systems converted from R22 where conversion is approved and carried out according to manufacturer requirements.

Important: R134a and R407C are not interchangeable. Always verify the refrigerant specified on the equipment nameplate and in the manufacturer’s service documentation.

Handling and Safety Precautions
  • Have refrigerant charging and servicing performed by qualified refrigeration technicians.
  • Follow the manufacturer’s safety data sheet and equipment servicing instructions.
  • Work in a well-ventilated area and avoid inhaling concentrated refrigerant vapour.
  • Avoid contact with liquid refrigerant, which can cause cold burns or frostbite.
  • Use suitable personal protective equipment and compatible refrigerant-handling tools.
  • Keep cylinders away from excessive heat and physical damage.
  • Do not mix refrigerants.
  • R407C is a zeotropic blend and is generally charged as a liquid according to the manufacturer’s instructions to help maintain its composition.
  • Use approved recovery equipment and never intentionally release refrigerant into the atmosphere.
  • Follow applicable regulations for refrigerant storage, transport, recovery, recycling, and disposal.
Environmental Considerations

R134a and R407C have zero ozone-depletion potential but contribute to global warming if released into the atmosphere. Their importation, distribution, use, and recovery may be regulated.

Before purchasing or supplying either refrigerant, confirm current requirements in the destination country. When considering an alternative refrigerant, a qualified technician should assess system compatibility, operating pressures, lubricant requirements, safety classification, and manufacturer approval.

Why Choose Metraflex Industrial Suppliers?

Metraflex Industrial Suppliers supports industrial, HVAC, and refrigeration customers across East Africa.

Contact our team to:

  • Discuss refrigeration and air-conditioning product requirements.
  • Confirm product specifications and technical documentation.
  • Check applicable supply and regulatory requirements.
  • Identify refrigerant options appropriate for compatible equipment.
Frequently Asked Questions

What is R134a refrigerant ?

R134a is in compatible refrigeration equipment, chillers, certain automotive air-conditioning systems, and other approved cooling applications.

What is R407C refrigerant ?

R407C is in compatible air-conditioning systems, heat pumps, and selected refrigeration applications.

Are R134a and R407C interchangeable?

No. They have different operating characteristics and equipment requirements. Use only the refrigerant specified or approved by the equipment manufacturer.

Do these refrigerants damage the ozone layer?

Both have an ozone-depletion potential of zero. However, they have global warming potential, so responsible handling and recovery are important.

How should R407C charged into a system?

Follow the equipment and refrigerant manufacturer’s instructions. R407C is a blended refrigerant and is generally charged as a liquid to help maintain the correct blend composition.

How can I enquire about these refrigerants in Kenya?

Contact Metraflex Industrial Suppliers for product information, technical documentation, and confirmation of applicable supply requirements.

Contact Metraflex Industrial Suppliers

Company: Metraflex Industrial Suppliers
Location: Dar es Salaam Road, Off Enterprise Road, Industrial Area, Nairobi, Kenya
Phone / WhatsApp: +254 117 254578
Email: metraflexindustrial@gmail.com
Supply Regions: Kenya, Tanzania, Uganda, and Ethiopia

Contact our team for refrigeration product information and technical documentation.

Reviews

There are no reviews yet.

Be the first to review “R134a R407C Gas in Kenya, Tanzania and Uganda”

Your email address will not be published. Required fields are marked *

Need Help Finding a Part?

Send us the product, size and quantity you need and we will confirm price and availability.

WhatsApp