At least 15.2 N/mm² on steel pins and collars after 24 hours at 22°C
Lap shear strength
Approximately 3.6 N/mm² on grit-blasted steel after 72 hours at 22°C
Maximum flange gap
Up to approximately 0.25 mm under specified conditions
Typical service temperature
Approximately -55°C to +150°C
Primary application
Sealing close-fitting rigid metal flanges
Typical equipment
Pumps, thermostats, compressors, transmission housings and axle covers
Values are typical manufacturer-reported results and depend on test conditions, substrate and joint design. Confirm current specifications in the manufacturer’s technical documentation before selecting the product.
Aluminium and steel; suitable rigid metal surfaces
Fluid Resistance
Oil, water and glycol, subject to application conditions
Primary Applications
Rigid metal flanges, gearbox casings, engine housings and pump housings
Packaging
Sizes vary by market and supplier
Specifications are based on Henkel’s published product information. Fixture time and curing performance depend on the substrate, temperature, surface condition and gap size. Consult the current technical data sheet for critical applications.